Ultimate-technology 500 POS Manuel d'utilisateur Page 54

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 80
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 53
46
Table 5. Remote Programming Mode Commands - Continued
OP
CODE
(HEX)
MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT
B2 SENDP
Sends data to selected port: main
serial port, auxiliary serial port, or
auxiliary keyboard port.
COMMAND: B2p...........<CR>
B2 = Op Code
p = data destination port
<CR> = terminate command (0D hex)
p:
0 = serial port 0 (main)
1 = serial port 1 (auxiliary)
2 = keyboard port 0 (main)
3 = keyboard port 1 (auxiliary)
4 = cash drawer 1 fire
5 = cash drawer 2 fire
Where data can be ASCII or CxDx (high and
low nibble hex value) type.
ACKNOWLEDGEMENT: NONE
B3 RDERROR
Sends all error information to main
port for output.
COMMAND: B3<CR>
B3 = Op Code
<CR> = terminate command (0D hex)
Sends all error log information contained in
the non-volatile memory (NVRAM) out the
main port.
ACKNOWLEDGEMENT: NONE
Vue de la page 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 79 80

Commentaires sur ces manuels

Pas de commentaire